NUMBER
|
DATE |
DRAWING TITLE |
S900-1 |
11/22/10 |
Water Trench Pavement Reconstruction (dwg) (dxf) (pdf) |
S900-2 |
11/22/10 |
Water Trench Pavement Rehabilitation (dwg) (dxf) (pdf) |
S900-3 |
11/22/10 |
Water Main Crossing Below Sewer (dwg) (dxf) (pdf) |
S900-4 |
8/7/13 |
Horizontal Thrust Block Domestic System (dwg) (dxf) (pdf) |
S900-5 |
6/1/09 |
Vertical Thrust Block Domestic System (dwg) (dxf) (pdf) |
S900-6 |
2/19/15 |
Disinfection Sampling Tap (dwg) (dxf) (pdf) |
S900-7 |
9/1/09 |
Water Main Pipe Restraint Domestic System (dwg) (dxf) (pdf) |
S900-8 |
9/1/09 |
Water Main Pipe Restraint Holly System (dwg) (dxf) (pdf) |
S900-9 |
8/7/13 |
Horizontal Thrust Block Holly System (dwg) (dxf) (pdf) |
S900-10 |
6/1/09 |
Vertical Thrust Block Holly System (dwg) (dxf) (pdf) |
S900-11 |
3/23/11 |
Replacement of 4 Inch and Larger Water Service on New Water Main (dwg) (dxf) (pdf) |
S900-12 |
4/29/11 |
Water Service Tap Excavation (dwg) (dxf) (pdf) |
S901-8 |
6/1/09 |
Plastic Water Main Tracer Wire Installation (dwg) (dxf) (pdf) |
S901-9 |
4/19/18 |
Plastic Water Service Tracer Wire Installation (pdf) |
S901-10 |
2/19/15 |
Plastic Water Main Tracer Wire End to End Splice Connection (dwg) (dxf) (pdf) |
S901-11 |
6/1/09 |
Plastic Water Service Tracer Wire Tap Splice Connection (dwg) (dxf) (pdf) |
S901-12 |
12/15/10 |
Impervious Clay Water Main Trench Plug (dwg) (dxf) (pdf) |
R905-1 |
6/1/09 |
Cutting-In Valve Installation (dwg) (dxf) (pdf) |
S909-1 |
6/17/21 |
Water Valve Box Adjustment or Replacement (pdf) |
S909-2 |
N/A |
Concrete Collar for Valve Box Within Roadway (Detail on Public Works Construction Details Page) |
S909-3 |
N/A |
Asphalt Restoration for Valve Box Within Roadway (Detail on Public Works Construction Details Page) |
S909-4 |
N/A |
Round Concrete Collar for Valve Box Within Roadway (Detail on Public Works Construction Details Page) |
S909-5 |
N/A |
Concrete Collar for Multiple Valve Boxes Within Roadway (Detail on Public Works Construction Details Page) |
S911-1 |
2/19/15 |
Pitometer Tap (dwg) (dxf) (pdf) |
R913-1 |
6/1/09 |
Water Service Pipe 2 Inch and Smaller (dwg) (dxf) (pdf) |
R913-2 |
6/1/09 |
Existing Copper Water Service Pipe Extension 2 Inch and Smaller (dwg) (dxf) (pdf) |
R913-3 |
11/24/20 |
Water Service Card (pdf) |
S916-1 |
6/1/09 |
Bypass Pipe Crossing at Driveway, Sidewalk and Street (dwg) (dxf) (pdf) |
S916-2 |
11/22/10 |
Bypass Pipe at Sidewalk Access Ramp (dwg) (dxf) (pdf) |
R917-1 |
1/25/17 |
Hydrant and Valve with New Branch (dwg) (dxf) (pdf) |
R917-2 |
1/25/17 |
Hydrant at Existing Branch (dwg) (dxf) (pdf) |
S920-2 |
9/16/13 |
Water Meter Vault for Domestic Meter 3 Inch to 10 Inch (dwg) (dxf) (pdf) |
S920-3 |
9/16/13 |
Water Meter Vault Dimensions and Notes (dwg) (dxf) (pdf) |
S922-1 |
2/25/14 |
Permanent Blow-Off Assembly (dwg) (dxf) (pdf) |
S924-1 |
5/10/11 |
Water Meter Pit 1 Inch and Smaller in Lawn Area (dwg) (dxf) (pdf) |
S924-2 |
5/10/11 |
Water Meter Pit 1-1/2 Inch and 2 Inch in Lawn Area (dwg) (dxf) (pdf) |
S925-1 |
5/11/11 |
Yard Hydrant (dwg) (dxf) (pdf) |
S962-1 |
9/16/13 |
Joint Bond for Metallic Water Main Pipe/Fitting (dwg) (dxf) (pdf) |
S966-1 |
12/28/10 |
Anode at New Ductile Iron Water Main or Ductile Iron Fitting on New Plastic Water Main (dwg) (dxf) (pdf) |
S966-2 |
12/28/10 |
Thermite Weld Details (dwg) (dxf) (pdf) |
S966-3 |
12/28/10 |
Anode at New Copper Water Service on Plastic Water Main (dwg) (dxf) (pdf) |
S966-4 |
12/28/10 |
Anode at New Water Service on Existing Cast/Ductile Iron Water Main (dwg) (dxf) (pdf) |
S966-5 |
12/28/10 |
Anode at Existing Ductile/Cast Iron Pipe Joint (Reconstruction) (dwg) (dxf) (pdf) |
S966-6 |
12/28/10 |
Anode at Existing Ductile/Cast Iron Pipe Joint (Rehabilitation) (dwg) (dxf) (pdf) |
S966-7 |
1/05/12 |
Anode at Insertion Sleeve and Cut-In Tee on Existing Iron Pipe (dwg) (dxf) (pdf) |
S966-8 |
11/03/14 |
Anode at Existing Ductile/Cast Iron Pipe Joint (Double Anodes) (dwg) (dxf) (pdf) |
S966-9 |
7/7/16 |
Anode at Tapping Sleeve and Valve on Existing Cast/Ductile Iron Water Main (dwg) (dxf) (pdf) |
S968-1 |
10/24/13 |
Cathodic Protection Test Station for Metallic Water Pipe or Fitting (1 of 2) (dwg) (dxf) (pdf) |
S968-2 |
10/24/13 |
Cathodic Protection Test Station for Metallic Water Pipe or Fitting (2 of 2) (dwg) (dxf) (pdf) |
S970-1 |
7/13/11 |
New Water Service 2 Inch and Smaller (dwg) (dxf) (pdf) |
S970-2 |
9/16/13 |
Indoor Installation of Water Meter 1 Inch and Smaller (dwg) (dxf) (pdf) |
S970-3 |
9/16/13 |
Indoor Installation of Water Meter 1-1/2 Inch and 2 Inch (dwg) (dxf) (pdf) |
S970-4 |
8/8/11 |
New Water Service 4 Inch and Larger on Existing Water Main (dwg) (dxf) (pdf) |
S970-5 |
8/11/11 |
New Water Service 4 Inch and Larger on Existing Water Main Notes (dwg) (dxf) (pdf) |
S970-6 |
8/8/11 |
Typical Indoor Installation of Domestic Water Meter 3 Inch to 10 Inch (dwg) (dxf) (pdf) |
S970-7 |
8/27/13 |
Typical Water Meter Installation for Holly Fire Service 4 Inch and Larger (dwg) (dxf) (pdf) |
S970-8 |
8/8/11 |
Typical Water Meter Installation for Domestic Fire Service 4 Inch and Larger (dwg) (dxf) (pdf) |
S970-9 |
3/8/12 |
Typical Combination Fire and Domestic Service (dwg) (dxf) (pdf) |
S971-1 |
6/21/11 |
Reduced Pressure Zone (RPZ) Backflow Prevention Device 2 Inch and Smaller (dwg) (dxf) (pdf) |
S971-2 |
6/21/11 |
Reduced Pressure Zone (RPZ) Backflow Prevention Device 2-1/2 Inch and Larger (dwg) (dxf) (pdf) |
S971-3 |
6/21/11 |
Reduced Pressure Zone (RPZ) Air Gap and Drain Line Installations (dwg) (dxf) (pdf) |